High Frequency Heart Rate Variability is Associated with Sensitivity to Affective Touch

Author: Ralph Pawling1, Francis McGlone2, Susannah C Walker3
Affiliation:
1 Research Centre for Brain & Behaviour, School of Psychology, Liverpool John Moores University, Liverpool, UK. Electronic address: s.c.walker@ljmu.ac.uk.
2 Research Centre for Brain & Behaviour, School of Psychology, Liverpool John Moores University, Liverpool, UK; School of Science, Department of Neuroscience and Biomedical Engineering, Aalto University, Finland. Electronic address: francis1.mcglone@gmail.com.
3 Research Centre for Brain & Behaviour, School of Psychology, Liverpool John Moores University, Liverpool, UK. Electronic address: r.pawling@ljmu.ac.uk.
Conference/Journal: Physiol Behav
Date published: 2024 Jun 1
Other: Pages: 114600 , Special Notes: doi: 10.1016/j.physbeh.2024.114600. , Word Count: 254


C-tactile afferents (CTs) are a class of unmyelinated, mechanosensitive nerve fibre that respond optimally to skin temperature, slow moving touch typical of a caress. They are hypothesised to signal the rewarding value of affiliative tactile interactions. While CT firing frequency is positively correlated with subjective ratings of touch pleasantness, trait differences in sensitivity to the specific hedonic value of CT targeted touch have been reported. Inter-individual differences in vagally mediated, high frequency heart rate variability (HF-HRV) have been linked to variation in visual social cognition. Thus, the aim of the present study was to examine the relationship between resting state HF-HRV and sensitivity to socially relevant CT targeted touch. 58 healthy participants first had a 5-minute electrocardiogram. They then rated the pleasantness of 5 randomly presented velocities of robotically delivered touch. Three velocities fell within (1, 3, 10 cm/s) and two outside (0.3, 30 cm/s) the CT optimal range. Each velocity was delivered twice. On a group level, affective touch ratings were described by a negative quadratic function, with CT optimal velocities rated as more pleasant than slower and faster speeds. Simple regression analysis confirmed participants' HF-HRV was significantly predicted by the quadratic curve fit of their touch ratings, with higher HF-HRV was associated with a better quadratic fit. These findings indicate that, in line with previous observations that higher HF-HRV is associated with enhanced sensitivity to visual social cues, trait differences in autonomic control could account for previously reported individual differences in CT sensitivity.

Keywords: Affective Touch, Heart Rate Variability; C-Tactile Afferent; Social; Touch.

PMID: 38830446 DOI: 10.1016/j.physbeh.2024.114600

BACK